Net Transceivers & Repeaters

Wireless Net Transceivers & Repeaters

RR2552B

Product data sheet:
application/pdf icon
rr2552 low.pdf
Product photo:
image
rr2552.jpg
RR2552B

The mesh network Series 2000 RR2552 signal repeater utilizes reliable Spread Spectrum Radio technology. It can be installed easily in minutes to increase the transmission distance between wireless sensors and the receivers.

The maximum radio transmission distance is dependent on building type. The maximum open air transmission distance between two repeaters is one mile. In a typical commercial building with steel I-beam construction, concrete floors with reinforcing rod, and metal stud walls, it can be expected that transmissions will penetrate vertically through floors and horizontally through 200 to 500 feet of walls, furniture and air.

Multiple repeaters can be used to extend the transmission distance to thousands of feet inside any commercial and industrial buildings.

The Series 2000 sensor Data & Link LED confirms the data transmission was received by the receiver for fast and reliable positioning of the repeaters during installation. There is no need for special wireless installation equipment or site survey tools. The Series 2000 wireless system can be used with any LON, BacNet, MODbus,
DDC control system or panel.

The RR2552 is covered by ACI's Two (2) Year Limited Warranty, which is located in the
front of ACI'S SENSORS & TRANSMITTERS CATALOG or can be found on ACI's web
site, which is: www.workaci.com.


RM9500

Product data sheet:
application/pdf icon
rm9500s2k low.pdf
Product photo:
image
rm9500.jpg
RM9500

The Series 2000 WebLogger utilizes reliable Spread Spectrum Mesh Network Radio technology. The RM9500 provides the user with Internet/intranet remote monitoring, control and logging capability.

It is a standalone internet web server that can communicate with all other sensors and controllers wirelessly. In addition, the RM9500 automatically and continuously logs all wireless sensor data such as temperature, humidity, tank level and alarm information for the last 30 days at 20 minute intervals.

Up to two (2 ) RC2105 controllers or 50 separate wireless sensors can be used with one RM9500 and up to 100 data points can be monitored and logged with one (1) RM9500 Weblogger.

The maximum radio transmission distance is dependent on building type. The maximum open-air transmission distance is one mile. In a typical commercial building with steel I-beam construction, concrete floors with reinforcing rod, and metal stud walls, it can be expected that transmissions will penetrate vertically through floors and horizontally through 200 to 500 feet of walls, furniture and air.

Generally a wireless system will cover at least three floors - one floor above and one floor below the receiver location. In some buildings with favorable transmission characteristics the system may cover more floors.

The RM9500 is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI'S SENSORS & TRANSMITTERS CATALOG or can be found on ACI's web site, which is: www.workaci.com.


MOD9200LON

Product data sheet:
application/pdf icon
MOD9200LON low.pdf
Product photo:
image
MOD9200LON rev2_s (1).jpg
MOD9200LON

The MOD9200LON network transceiver utilizes reliable Spread Spectrum Mesh Network Radio technology. Together with other wireless sensors and controls, the system can be used to transmit remote sensor readings, status/alarm indications, control signals and outputs wirelessly. It is compatible with control networks or automation systems that utilize LonWorks® communication protocol or interface. Up to 50 separate physical wireless sensor transmitters and/or wireless remote output (analog & digital) modules can be used with one MOD9200LON Transceiver and up to 100 data points and 100 wireless outputs can be monitored and controlled with one (1) MOD9200 Transceiver.

The maximum radio transmission distance is dependent on building type. The maximum open air transmission distance is one mile. In a typical commercial building with steel I-beam construction, concrete floors with reinforcing rod, and metal stud walls, it can be expected that transmissions will penetrate vertically through floors and horizontally through 200 to 500 feet of walls, furniture and air.

Generally a wireless system will cover at least three floors - one floor above and one floor below the transceiver location. In some buildings with favorable transmission characteristics the system may cover more floors.

The MOD9200LON is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI'S SENSORS & TRANSMITTERS CATALOG or can be found on ACI's web site, which is: www.workaci.com.

Note: LonWorks is a registered trademark of the Echelon Corporation.


MOD9200D

Product data sheet:
application/pdf icon
mod9200d low.pdf
Product photo:
image
MOD9200LON rev2_s (1).jpg
MOD9200D

The Series 2000 MODBUS network transceiver utilizes reliable Spread Spectrum Mesh network Radio technology. Together with other wireless sensors and controls, the system can be used to transmit remote sensor readings, status/alarm indications and control signals wirelessly. It is compatible with any control systems or Programmable Logic Controller (PLC) panels that utilize MODBUS communication protocol or interface. Up to 50 separate physical wireless sensor transmitters and/or wireless remote output (analog & digital) modules can be used with one MOD9200D Transceiver and up to 100 data points and 100 outputs can be monitored and controlled with one (1) MOD9200 Transceiver.

The maximum radio transmission distance is dependent on building type. The maximum open-air transmission distance is one mile. In a typical commercial building with steel I-beam construction, concrete floors with reinforcing rod, and metal stud walls, it can be expected that transmissions will penetrate vertically through floors and horizontally through 200 to 500 feet of walls, furniture and air.

Generally a wireless system will cover at least three floors - one floor above and one floor below the transceiver location. In some buildings with favorable transmission characteristics the system may cover more floors.

The MOD9200D is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI'S SENSORS & TRANSMITTERS CATALOG or can be found on ACI's web site, which is: www.workaci.com.


MOD9200BNT

Product data sheet:
application/pdf icon
mod9200bnt low.pdf
Product photo:
image
MOD9200LON rev2_s (1).jpg
MOD9200BNT

The Series 2000 BACnet® network transceiver utilizes reliable Spread Spectrum Mesh Network Radio technology. Together with other wireless sensors and controls, the system can be used to transmit remote sensor readings, status/alarm indications, control signals and outputs wirelessly. It is compatible with any control panels or Automation Systems that utilize BACnet MSTP (Master Slave Token Passing) communication protocol or interface. Up to 50 separate physical wireless sensor transmitters and/or wireless remote output (analog & digital) modules can be used with one MOD9200BNT Transceiver and up to 100 data points and 100 outputs can be monitored and controlled with one (1) MOD9200 Transceiver.

The maximum radio transmission distance is dependent on building type. The maximum open-air transmission distance is one mile. In a typical commercial building with steel I-beam construction, concrete floors with reinforcing rod, and metal stud walls, it can be expected that transmissions will penetrate vertically through floors and horizontally through 200 to 500 feet of walls, furniture and air.

Generally a wireless system will cover about three floors - one floor above and one floor below the transceiver location. In some buildings with favorable transmission characteristics, the system may cover more floors.

The MOD9200BNT is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI'S SENSORS & TRANSMITTERS CATALOG or can be found on ACI's web site, which is: www.workaci.com.


        